Skip to content
PoolBuff

Pentair · System:3

Pentair Sta-Rite System:3 Modular D.E.

Pentair's Sta-Rite System:3 modular D.E. filter: one module in place of grids, the flow its own brochure sets lower, and seven clamps to tighten in order.

A matte black D.E. pool filter on a concrete pad beside a pool, a pressure gauge on its domed, ribbed top and a ring of clamps with round knobs around its middle
Generated image, checked against Pentair’s own product photographs. It is not a photograph of this unit.

The System:3 Modular D.E. is Sta-Rite's D.E. filter with one pleated module where most D.E. filters have a stack of grids. Pentair owns the Sta-Rite name and still sells the filter under it. The powder coats the module the way it coats grids, and the filter backwashes like any D.E. filter. The difference comes when backwashing isn't enough. Take the lid off and hose the module down in the tank, with no grid pack to pull apart.

Pentair's other answer to the same problem is the Quad D.E., with four cartridges instead of one module. Its grid filter is the FNS Plus. Sta-Rite's System:3 cartridge and System:3 sand filters share this one's tank top, cord ring and clamps. Sand, cartridge or D.E. covers how the three types compare.

Two sizes, one tank

There are two models, and they share everything but the module:

  • S7MD60: 60 square feet, 9 lb of D.E., rated up to 120 gallons a minute
  • S7MD72: 72 square feet, 11 lb of D.E., rated up to 144

Those maximums work out to 2 gallons a minute per square foot, and the manual gives the same figures as the NSF public pool rate. Pentair's own brochure sets the bar lower. It lists the filter's best performance at 60 to 90 gallons a minute on the S7MD60 and 72 to 108 on the S7MD72. The 2025-2026 catalog splits the difference, quoting 1 to 2 gallons a minute per square foot. So if the pump pushes more than about 90 gallons a minute, the S7MD72 is the one that stays inside the brochure's range.

The bigger module isn't the cheaper one to keep. At US list, the S7MD72's module costs $1,687.03 against $1,017.85 for the S7MD60's: about two-thirds more money for a fifth more area. Filter sizing covers matching the area to your pump.

Use only the D.E. the label calls for. The manual warns that more causes "bridging" between the pleats and plugs the filter. Half a pound of D.E. fills a one-pound coffee can, by its reckoning, so 9 lb is about 18 cans.

Seven clamps, in order

The two halves of the tank are held by seven Posi-Lok clamps with hand knobs. Before touching them, stop the pump, open the air release valve on top, and wait until all the pressure is out and the water has drained. The manual warns that a filter adjusted or taken apart under pressure can explode.

  • Taking it apart: loosen the knobs alternately, on opposite sides of the tank, so the flange stress stays even.
  • Putting it back: seat the tank o-ring evenly with the sealing surfaces clean, fit all seven clamps, then tighten the knobs hand-tight in the crisscross order the manual draws. Don't work your way around from one clamp to the next.

Don't lubricate the tank o-ring. The manual says lubricant attracts dirt and grit, and that petroleum products in particular can damage the o-ring and void the warranty. Pentair's Quad D.E. guide allows silicone on its o-ring, so don't carry that habit over.

The tank shells are the expensive parts: the upper is $1,505.28 and the lower $1,680.92 at US list.

Starting it up

Every startup follows the same steps:

  1. With the pump off, check that the clamps are on and hand-tight, and set the valve to Filter.
  2. Fill the pump's trap with water, open the air release valve, and start the pump.
  3. Close the valve when a steady stream of water comes out of it.
  4. Mix the D.E. with water and pour it slowly into the skimmer.
  5. Write down the pressure. Every cleaning decision is measured from it.

The manual's warnings are short. Never run the filter without its D.E. coat, or the module's fabric is damaged. Never change the valve handle while the pump is running. Never go above 50 psi. On a new pool, open the filter after about 48 hours and clean out what it caught.

Cleaning: bump, backwash, then the module

When the gauge reads 10 psi above the starting pressure, the manual's first step isn't a backwash. Stop the pump for 30 to 60 seconds so the D.E. cake falls off the module, then restart it to form a new one. If the pressure is still 10 psi high, backwash:

  1. Stop the pump and set the valve to Backwash.
  2. Run the pump for 3 minutes.
  3. Stop it, and open the drain in the side of the tank. Sta-Rite recommends a 1½-inch drain valve there.
  4. Run the pump 1 more minute, backwashing through the valve and the side drain together.
  5. Stop the pump, return the valve to Filter, and close the drain. Then add a fresh D.E. coat, since the manual says never to run the filter without one.

Then compare the gauge with your starting reading. If the two aren't close, the module needs cleaning by hand.

Only two valves are approved: the 18201-0300 2-inch multiport and the 263053 push-pull slide valve. The manual warns that any other valve could send water through the filter backward and damage the internals. Pentair sells both separately, through dealers.

Cleaning the module. With the pressure out and the tank drained, hose the module down in the tank with a soft nozzle, then lift it out and spray the whole surface. Clean the air bleed screen on top every time the filter is open. The manual asks for this at least twice a year, and a soak in a filter cleaner at least once a year for oils and scale. The filter cleaning guide covers the soak.

Three cautions from the same pages. Don't acid-clean the module yourself; the manual says that's a job for a pool professional. Don't leave it in the sun for long. And if your pool runs on a PHMB sanitizer such as biguanide, clean it only with PHMB cleaners, or the warranty is void.

When D.E. gets into the pool

The manual's list for water that won't come clear names a broken module passing D.E. into the pool, and its fix is to replace it. The same list names too little D.E. or a poor coat, and an inlet and outlet plumbed backward. D.E. in the pool walks through finding which it is.

A module that looks matted isn't necessarily done. The manual says the pleats can look that way after use, and the filter is working as long as the D.E. still sticks to them.

Winter

Letting the filter freeze damages it and voids the warranty. Clean the module first: the manual says not to winterize with D.E. still on it. Then open the air release valve and the system valves, pull the drain plugs, loosen the unions, and drain. The outlet pipe won't empty through the filter's drain, so it needs its own. Take the module out and store it somewhere warm, dry and out of the sun. Then cover the filter.

If you blow the lines out, the manual allows only a low-pressure blower, below 5 psi. Compressed air can make components explode. Blowing out pool lines covers the rest.

Not the filter in the 2004 recall

CPSC and Sta-Rite recalled about 8,500 filters in 2004, a recall the leaking filter guide mentions. That covered the smaller System 2 filters, with model numbers starting PLM or PLD, and AquaTools filters, not the System:3. The cartridge System:3, the SM Series with models from S7M120 up, is a different filter with different modules.

Where you buy it

Pentair sells both sizes only through dealers, and both are on its TradeGrade list. It lists no online EC- version.

That decides the warranty. From a store, builder or service company and professionally installed, it's two years, parts and labor. Without a professional install, or bought online, it's one year, parts only. Pentair's consumables, covered for a year, include o-rings, gaskets, cartridge elements and D.E. grids. Its list doesn't name a module, so ask the dealer how it treats one.

Which model do you have?

The model number is on the filter label. Everything else in the range is shared — these are the parts that change with it.

ModelSKUFilter areaD.E. chargeMaximum flowModule
S7MD60, 60 sq. ft.S7MD6060 sq. ft.9 lb120 GPM; the brochure's best performance is 60 to 9025023-0160S, $1,017.85 US list

Note on S7MD60, 60 sq. ft.: Dealer only. The same tank as the S7MD72; the module, the D.E. charge and the decals are what differ.

S7MD72, 72 sq. ft.S7MD7272 sq. ft.11 lb144 GPM; the brochure's best performance is 72 to 10825023-0172S, $1,687.03 US list

Note on S7MD72, 72 sq. ft.: Dealer only. A fifth more area than the S7MD60, in the same tank.

Pentair Sta-Rite System:3 Modular D.E. parts, and what goes wrong

Read off the manufacturer’s parts list and checked before it ships. Open a row for what a bad one actually does — or start from the symptom and work down, which is the cheaper order.

What is it doing?

If you are doing the job anyway

Opening the filter to clean the module puts the tank o-ring and the air bleed screen in your hand. Numbers carry the Z the 2025-2026 catalog prints; the 2012 manual leaves it off.

Module cleaning

The manual has you inspect the tank o-ring every time the tank comes apart, and clean the air bleed screen every time the filter is opened. Both are cheap next to a leak or a short cycle at restart.

  • Tank o-ring24850-0008Z
  • Air bleed assembly24800-0120

D.E. in the pool

The manual names a broken module as what passes D.E. into the pool. The air bleed assembly and the baffle kit come with a new module, so check the size before ordering.

  • Replacement module, S7MD6025023-0160S
  • Replacement module, S7MD7225023-0172S

Pentair Sta-Rite System:3 Modular D.E. manuals and documentation

Hosted by the manufacturer. These open on Pentair’s own servers, so they stay current.

Pentair Sta-Rite System:3 Modular D.E. warranty

2 years parts, Included when bought from a dealer and professionally installed labor

Two years. Pentair's warranty table gives every filter that term, for one bought from a store, builder or service company and professionally installed. Without a professional install it's one year, parts only, and anything bought online, including from an authorized online reseller, gets one year of parts only from the date of purchase. Both sizes are on Pentair's TradeGrade list, sold only through stores, builders and service companies. Pentair counts o-rings, seals, gaskets, cartridge elements and D.E. grids as consumables, covered for one year; its list doesn't name a module. Buy a Pentair pump, a filter and one more eligible product on one invoice from a store, builder or service company, and register it, and the whole set gets three years. Letting the filter freeze voids its warranty, the manual says.

Manufacturer’s terms

Pentair Sta-Rite System:3 Modular D.E. complete parts list

Every part on the manufacturer’s exploded diagram, in their numbering. Marked rows are the ones covered above with a symptom and a diagnosis.

35 parts

No.PartDescriptionNote
133600-0023TGauge, 2 in. what goes wrong$72.10 US list
2WC8-72DScreen filterThe 2012 manual only; the 2025-2026 catalog has no row for item 2
3154689ZAir release valve what goes wrong2025-2026 catalog. The 2012 manual prints WC212-120P. $45.64 US list
435202-0959Close nipple, 1/4 in.$21.10 US list
524900-0504ZAdapter bushing$28.09 US list
635505-1423ZO-ring$3.22 US list
724851-9000Upper tank shell kitIncludes all decals and labels. $1,505.28 US list
824850-0008ZTank o-ring what goes wrong$96.60 US list
9A25023-0160SReplacement module, S7MD60 what goes wrong$1,017.85 US list
9A25023-0172SReplacement module, S7MD72 what goes wrong$1,687.03 US list
9B24800-0120Air bleed assembly what goes wrongIncluded with a module. $33.22 US list
1023910-0013SBaffle kit, with screwsIncluded with a module. $54.03 US list
1137207-0728Baffle screwsIncluded with a module. 2025-2026 catalog, price on request; the 2012 manual prints 37027-7028, four required
1223910-0100SElbow and bulkhead assemblyIncludes the o-ring, item 13. $188.65 US list
1335505-7438O-ring$15.62 US list
1423910-0101SDeflector and bulkhead assembly$125.78 US list
1535505-1425ZO-ringTwo required. $24.90 US list
1627001-0022ZPlug, 1½ in., with o-ring2025-2026 catalog. The 2012 manual prints 27001-002S. $4.45 US list
1724900-0509ZAdapter fitting$43.18 US list
1835505-1424ZO-ringTwo required. $14.92 US list
1924900-0503ZDrain plug$42.97 US list
2024752-0050ZBulkhead retaining nutTwo required. $37.12 US list
2124850-0102SLower tank shell$1,680.92 US list
2224850-0010ZClamp boltSeven required. $47.59 US list
2324850-0200ZClamp assembly what goes wrongSeven required. $196.50 US list
—23910-1100SSystem:3 modular D.E. conversion kitItems 12 to 16; the module is bought separately. $287.53 US list
—32165-4004Warning decal, S7MD60The 2012 manual
—32165-4005Warning decal, S7MD72The 2012 manual
—32155-4147Nameplate decal, S7MD60The 2012 manual
—32155-4148Nameplate decal, S7MD72The 2012 manual
—1000001338Instruction label decalThe 2012 manual
—PKG 188ZUnion by 2 in. slip adapter, pack of 22025-2026 catalog. The 2012 manual's 2 in. slip union kit is PKG 188
—PKG 189Union by 2 in. FPT adapter, pack of 22025-2026 catalog
—18201-0300Multiport valve, 2 in., with union connectionsSold separately. One of the two valves the manual approves
—263053Push-pull slide valve, 7.81 in. centersSold separately. The other approved valve