Pentair · Posi-Clear
Pentair Sta-Rite Posi-Clear RP
Sta-Rite's single-cartridge filter in three sizes: the parts it shares with Pentair's Clean & Clear, the flow Pentair recommends, and the lock ring done right.

The Posi-Clear RP is Sta-Rite's single-cartridge filter, sold by Pentair, which owns the Sta-Rite name. One pleated cartridge sits on a center core in a black tank, under a lid held by a lock ring. Pentair's page lists three sizes as current, through dealers: the PXCRP100, PXCRP150 and PXCRP200, item numbers 160351, 160352 and 160350.
Pentair's Clean & Clear, in a Sta-Rite tank
Most of its parts carry the same numbers as Pentair's Clean & Clear. The air relief valve, the gauge, the lock ring, the body O-ring, the air bleed sock kit and both center cores match, and the 2016 parts sheet gave the same cartridge numbers. The lids and the tank bottom are the Posi-Clear's own. So are the unions, which spin on with a diamond seal.
Sta-Rite's other cartridge filter is the two-cartridge System:3. Sand, cartridge or D.E. covers how the three filter types compare.
Three sizes, two tanks
- PXCRP100: 100 square feet, 33 inches tall, and 61 inches of headroom to lift the cartridge out.
- PXCRP150 and PXCRP200: 150 and 200 square feet in the same 40½-inch tank, with 76 inches of headroom. They share a lid and a center core, but not a cartridge.
Pentair rates them at 1 GPM per square foot but recommends half that, and nothing above 150 GPM. That's why the PXCRP200 carries the same 150 GPM rating as the PXCRP150. At the recommended 0.5 GPM per square foot, the three sizes come to 50, 75 and 100 GPM. Commercial pools get a lower cap: 0.375 GPM per square foot, or 38, 56 and 75 GPM.
Startup, and the two warning signs
The warning the manual repeats most is that air trapped in the filter can blow the lid off. Its maximum working pressure is 50 psi, pressure tests included.
- Seat the lid fully on the tank, then turn the lock ring clockwise until the latches click and it hits the stops. Don't over-tighten it.
- Open the air relief valve a quarter turn counterclockwise, until it snaps fully open.
- Stand clear of the filter and start the pump.
- Close the air relief valve when a steady stream of water comes out.
Two signs say something's wrong: no solid stream within 30 seconds of the pump basket filling, or the gauge showing pressure before any water comes out. Either way, shut the pump off right away, open the return valves to let the pressure out, and clean the air relief valve.
Write down the starting pressure on a clean cartridge. On a variable-speed pump, the manual says to write down the speed too, because the starting pressure depends on it.
Cleaning it
Clean the cartridge when the gauge reads 8 to 10 psi above the starting pressure, or when the flow drops noticeably.
- Pump off and automatic controls off. Open the air relief valve, and the drain cap if there is one.
- Push both safety latches in and turn the lock ring counterclockwise.
- Lift the cartridge out by its handles, and slide it off the center core.
- Hose it inside and out, turning it over several times.
- For oils, from sunscreen and swimmers, soak it for at least an hour in a filter cleaner, or in one cup of trisodium phosphate or dishwasher detergent to five gallons of water. Then rinse it well. The manual warns that an acid soak with oil still in the cartridge permanently restricts it.
- Spray out the tank base, and clean the O-ring and its groove.
- Slide the cartridge back on the core, and set the core in with its arrow lined up with the inlet. Check the internal air relief screen is on top.
- Coat the O-ring generously with silicone lubricant, seat the lid, and lock the ring.
That last step is the opposite of some filters' advice. The System:3 manual, for one, says never to lubricate its seal. Each tank wants what its own manual says.
The manual gives the cartridge an average life of three years, varying with swimmers, wind and dust. The filter cleaning guide covers when a cartridge needs more than a hose.
Cleaning the air relief valve
With the pump off and the gauge at zero, pull out the valve's locking tabs, turn its stem and cover counterclockwise, and lift them straight out. Clean off any debris. Push a 5/16-inch drill bit through the valve body to check the air passage into the tank is clear. Check the stem's O-rings, lubricate them with silicone or PTFE lubricant only, and push the stem back in with a clockwise turn until it snaps.
What the troubleshooting section says
- Air getting in is the first thing to fix. Signs include a low water level, bubbles in the pump basket or at the returns, and air coming out when you open the air relief valve with the pump running.
- Short cycles on a new pool are normal until the fill water has been filtered, and plaster dust can cause them too.
- Falling pressure: check the skimmer and pump baskets first. If they're clean, turn the motor shaft by hand with the power off. If it turns freely, the manual says to check the impeller for a clog, then the suction line.
Installing it
Set it on a level concrete slab where you can see the gauge and the lock ring all the way around, with the headroom above to lift the cartridge out. Point the air relief valve and the drain away from anything electrical. The unions and bulkhead connections seal on O-rings, so no pipe joint compound, glue or solvent. Pentair's page and catalog give 104°F as the maximum water temperature inside the filter.
Where you buy it
Pentair sells all three sizes through dealers only, and they're on its TradeGrade list. From a store, builder or service company and professionally installed, the filter gets two years, parts and labor. Without a professional install, or bought online, it's one year, parts only.
Where Pentair's documents disagree
- The drain. The brochure says 1-1/2 inches, the 2025-2026 catalog 1 inch.
- The drain cap. The manual lists 154712Z before October 2017 and 190030Z after. The catalog's Posi-Clear page lists only 154712Z.
- The cartridges. The 2025 manual and the catalog list Pleatco Ultra cartridges, ULTRA-C3 to ULTRA-C5. The 2016 parts sheet gave R173215 to R173217.
- The core. The catalog calls the cartridge coreless, while its own parts list sells a center core for each size. The cartridge has no core of its own; it slides over one.
- The model names. The brochure and catalog say PXCRP; the manual says PCRP.
- The brochure's date. Its file name says 2025, but the brochure is marked P1-148, April 2020.
Which model do you have?
The model number is on the filter label. Everything else in the range is shared — these are the parts that change with it.
| Model | SKU | Area | Max flow | Headroom | Cartridge |
|---|---|---|---|---|---|
| PXCRP100 | 160351 | 100 sq. ft. | 100 GPM | 61 in. | ULTRA-C3 |
Note on PXCRP100: The manual calls it the PCRP 100. A 33 in. tank, with its own lid, 59053001Z, and center core, 59053700. | |||||
| PXCRP150 | 160352 | 150 sq. ft. | 150 GPM | 76 in. | ULTRA-C4 |
Note on PXCRP150: A 40½ in. tank. The lid, 178745Z, and center core, 59053800, are the PXCRP200's too; the cartridge isn't. | |||||
| PXCRP200 | 160350 | 200 sq. ft. | 150 GPM | 76 in. | ULTRA-C5 |
Note on PXCRP200: Rated at the same 150 GPM as the PXCRP150, because Pentair recommends nothing above 150. | |||||
Pentair Sta-Rite Posi-Clear RP parts, and what goes wrong
Read off the manufacturer’s parts list and checked before it ships. Open a row for what a bad one actually does — or start from the symptom and work down, which is the cheaper order.
What is it doing?
The seal between the lid and the tank, the same number as on Pentair's Clean & Clear. Clean it and its groove every time the tank opens, and coat it generously with silicone lubricant before the lid goes back. Never use a petroleum lubricant: the manual says it damages the equipment. $15.51 US list.
Never touch it with any pressure in the filter. To take it off, push both safety latches in and turn the ring counterclockwise. To put it back, seat the lid fully, then turn the ring clockwise until the latches click and it hits the stops, and no further: the manual says not to over-tighten it. $157.66 US list.
A quarter turn counterclockwise snaps it fully open. At startup, a solid stream should come out within 30 seconds of the pump basket filling. If it doesn't, or the gauge shows pressure first, shut the pump off, open the return valves to let the pressure out, and clean the valve: pull out its locking tabs, turn the stem and cover counterclockwise, lift them straight out, and push a 5/16 in. drill bit through the valve body to check the air passage is open. $54.90 US list.
The manual's test: it should read zero with the system off and the pressure let out, show pressure when the pump runs, and be readable and undamaged. If it fails any of those, replace it. $13.93 US list.
Pentair's Pleatco Ultra cartridge for the 100 sq. ft. size; the 150 takes ULTRA-C4 and the 200 ULTRA-C5. The manual gives an average life of three years. The 2025-2026 catalog prices all three on request. The 2016 parts sheet listed R173215, R173216 and R173217, the numbers Pentair's Clean & Clear page gives for its 100, 150 and 200.
The support tube the cartridge slides onto, lifted out with it by the handles. When it goes back, line the arrow on it up with the filter's inlet and make sure the internal air relief screen is on its top. $219.01 US list; the PXCRP150 and PXCRP200 take 59053800 at $335.65.
The seal in each plumbing union. The manual says to lubricate union and bulkhead o-rings with PTFE or silicone lubricant only, and to use no pipe joint compound, glue or solvent on the bulkhead connections. $6.66 US list; the union nut is U11-200PSZ at $17.38.
The manual lists 190030Z for filters made after October 2017 and 154712Z for older ones. The catalog's Posi-Clear page lists only 154712Z, as a drain plug kit priced on request, and prices 190030Z, at $47.78, on its Clean & Clear RP and FNS Plus pages.
If you are doing the job anyway
Numbers carry the Z the 2025-2026 catalog prints where it lists the part.
New cartridge, PXCRP100
The tank is open anyway, and the manual wants the body O-ring clean and lubricated every time it is. Replace it if it's flattened or cut.
- Cartridge, PXCRP100ULTRA-C3
- Body O-ring87300400Z
Pentair Sta-Rite Posi-Clear RP manuals and documentation
Hosted by the manufacturer. These open on Pentair’s own servers, so they stay current.
- Posi-Clear RP cartridge filter installation and user's guide (P/N 178736 Rev. D, 8/20/25)manual
- Posi-Clear RP product page: the three sizes and the operating limits, dealer onlyspec
- Posi-Clear RP brochure (P1-148, April 2020)spec
- Pentair Pool 2025-2026 product catalog, cartridge filters: the Posi-Clear RP on page 60, with the dimensionsspec
- Pentair Pool 2025-2026 product catalog, filter parts: the PXC Series on page 340, with US list pricesdiagram
- PXC Series replacement parts, the older catalog page (PDF 2016)diagram
- Pentair pool and spa equipment warranty informationspec
Pentair Sta-Rite Posi-Clear RP warranty
2 years parts, Included when bought from a store, builder or service company and professionally installed labor
Two years: Pentair's warranty table gives all filters that term. All three sizes are on Pentair's TradeGrade list, revised October 23, 2026, which Pentair means for stores, pool builders and service companies, and it says in-ground TradeGrade products carry parts and labor coverage. Not professionally installed, it's one year, parts only. Bought online, even from an authorized online reseller, it's one year, parts only, from the date of purchase. Cartridge elements, o-rings and gaskets are consumables, with one year of parts and labor. Bought on one invoice with a Pentair pump and at least one more eligible Pentair product from a store, builder or service company, and installed at the same home, Pentair's bundle program extends the warranty to three years.
Manufacturer’s termsPentair Sta-Rite Posi-Clear RP complete parts list
Every part on the manufacturer’s exploded diagram, in their numbering. Marked rows are the ones covered above with a symptom and a diagnosis.
23 parts
| No. | Part | Description | Note |
|---|---|---|---|
| 1 | 98209800 | High Flow manual air relief valve what goes wrong | $54.90 US list |
| 2 | 190058Z | Pressure gauge what goes wrong | $13.93 US list. Printed 190058 in the manual |
| 3 | 59053001Z | Lid, PXCRP100 | $256.25 US list |
| 4 | 178745Z | Lid, PXCRP150 and PXCRP200 | $238.92 US list |
| 5 | 59052900Z | Lock ring assembly what goes wrong | $157.66 US list |
| 6 | 87300400Z | Body O-ring what goes wrong | $15.51 US list |
| 7 | 59016200 | Air bleed sock kit | $21.06 US list |
| 8 | 59053700 | Center core, PXCRP100 what goes wrong | $219.01 US list |
| 9 | 59053800 | Center core, PXCRP150 and PXCRP200 | $335.65 US list |
| 10 | ULTRA-C3 | Pleatco Ultra cartridge, PXCRP100 what goes wrong | Priced on request |
| 11 | ULTRA-C4 | Pleatco Ultra cartridge, PXCRP150 | Priced on request |
| 12 | ULTRA-C5 | Pleatco Ultra cartridge, PXCRP200 | Priced on request |
| 10 | R173215 | Cartridge element, PXCRP100 | The 2016 parts sheet |
| 11 | R173216 | Cartridge element, PXCRP150 | The 2016 parts sheet |
| 12 | R173217 | Cartridge element, PXCRP200 | The 2016 parts sheet |
| 13 | 178743Z | Tank bottom | $555.33 US list |
| 14 | 154712Z | Drain cap assembly, filters made before October 2017 | Listed as a drain plug kit, priced on request, on the catalog's Posi-Clear page; $47.76 US list on its Clean & Clear RP page |
| 14 | 190030Z | Drain cap assembly, filters made after October 2017 what goes wrong | The manual. $47.78 US list on the catalog's Clean & Clear RP and FNS Plus pages |
| 15 | 178732Z | Union nut C clip | $12.32 US list |
| 16 | U11-200PSZ | Union nut | $17.38 US list |
| 17 | 178746Z | Union diamond seal what goes wrong | $6.66 US list |
| 18 | 178733Z | Union, threaded half | $70.54 US list |
| 19 | 170097 | Air relief parts kit | The 2016 parts sheet only |