Pentair · iChlor
Pentair iChlor
Pentair's discontinued iChlor 15 and 30: the right replacement for each, the salt lights, wiring it to run with the pump, and what every code means.
Superseded. Replaced by the IntelliChlor PLUS and LT, which Pentair names as the recommended replacement. Everything on this page still applies to the units already installed.

The iChlor is Pentair's smaller salt chlorine generator, with its controls on the cell: a display, salt and status lights, and LESS and MORE buttons under a flip-up lid. It came in two sizes, the iChlor 15 for pools up to 15,000 gallons and the iChlor 30 for pools up to 30,000.
Both are discontinued. Pentair's 2025-2026 catalog marks all four iChlor numbers discontinued, each with a replacement, and the product page sends buyers to the IntelliChlor Plus and LT. This page is for keeping one running and for replacing it.
Which one you have
- iChlor 30: 1.0 lb of chlorine per 24 hours, run from a PC100 power center, 520556, the same one the IntelliChlor IC20 to IC60 use. 523081 is the cell with the power center, and 523009 the cell alone.
- iChlor 15: 0.6 lb per 24 hours, with its own power pack, 522741Z, that plugs into a 110-volt GFCI outlet. 523080 is the cell with the power pack, and 523010 the cell alone.
The power supplies don't swap. The manual says the iChlor 15 power pack is only for the iChlor 15 cell, and plugging any other iChlor cell into it will cause severe damage. An old IntelliChlor IC15 power pack can't run an iChlor either: the cell shows AC on its display.
Replacing a worn-out cell
The manual expects about 10,000 hours, roughly five years of average use. Hold MORE for 3 seconds to enter diagnostic mode, and the first screen is the cell's total hours.
Pentair's catalog names a replacement for each number:
- 523009, iChlor 30 cell: 523730, the PLUS30 cell
- 523081, iChlor 30 with power center: 523733, the PLUS30 with a PC100
- 523010, iChlor 15 cell: 523741, the LT15 cell
- 523080, iChlor 15 with power pack: 523744, the LT15 with its own power pack
The PLUS30 and LT15 are the same length as the iChlor, and Pentair says the thread size and unions are the same, so the new cell goes into the old plumbing. A PLUS30 runs on the iChlor 30's PC100.
On an iChlor 15, don't keep the old power pack. The catalog's replacement for the cell alone is the LT15 cell, 523741, but Pentair's Plus and LT manual says an LT15 connected to an older IntelliChlor or iChlor power pack is permanently damaged. Buy the LT15 with its own power pack, 523744.
Installing it
- After the filter and the heater, at least 3 feet from the heater outlet, and at least 5 feet from the pool's inside wall.
- Vertical if possible, with 12 to 18 inches of straight pipe before the inlet, and the arrow on the side pointing with the flow.
- Any in-line chlorine or bromine feeder goes after the cell. The manual says one before it will damage the cell permanently.
- On a pool and spa, before the pool and spa return valve, so both get chlorine and gas isn't trapped in the pipes.
- 20 to 105 gpm. Over 80 gpm, which includes in-floor cleaning systems and booster pumps, it needs a bypass loop with a flow control valve. With an in-floor cleaner, Pentair recommends giving the cleaner its own return line.
- Schedule 80 couplings, rated to 50 psi at 70°F.
- On a new pool, fit the spacer cell, 522965, for 30 days to flush the pipes, and wait at least a month after plastering before adding salt or running the cell.
The iChlor 30's power center mounts vertically, within 15 feet of the cell. The cell's four-pin cord plugs into its bottom and locks with the round nut. Pentair recommends a GFCI on its circuit but doesn't require one, and wired to the load side of an automation panel's filter pump relay, it needs none.
The iChlor 15's power pack mounts within 15 feet as well, on a 15-foot cord, and plugs into a 110-volt GFCI outlet. That outlet still has to be switched with the pump.
With Pentair automation, a four-wire 22 AWG cable runs from the PC100 to the panel's COM port: J20 on EasyTouch, J7 or J8 on IntelliTouch, J11 on SunTouch. The colors are red to +15, yellow to +DT, green to −DT and black to ground. Only one iChlor goes on a system. The panel then sets the output, and the cell's buttons stop working. Pentair's IntelliConnect talks to it too.
Without automation, a PC100 gives the iChlor two extras. Connected to an IntelliFlo pump's RS-485 cable, it won't make chlorine unless the pump is running. With a dry-contact signal from an automatic cover, it drops to 5 percent the first time the cover closes, remembers whatever you set after that, and caps the output at 50 percent while the cover is shut.
Salt, and what the lights say
The manual wants 3,600 ppm, within 3,000 to 4,500. That's a wider band than the IntelliChlor's own English table gives. The salt light:
- Green: 3,000 to 4,500 ppm.
- Flashing green: above 4,500. It keeps working, but high salt raises the risk of corrosion. Drain some water and refill.
- Red: 2,600 to 3,000. It makes chlorine less efficiently. Add salt.
- Flashing red: 2,000 to 2,600, and about 25 percent less chlorine. Below 2,000 the light flashes red too, and the cell stops.
The cell's reading is good to ±300 ppm. It checks at power-up and every 2 hours, and the salt lights scroll for 2 minutes while it does at power-up. Diagnostic mode shows the number: hold MORE for 3 seconds, then press MORE until the salinity screen.
Adding salt: test first, then use the manual's chart or the salt calculator. Use salt at least 99.8 percent sodium chloride, non-iodized, with no anti-caking agent. No rock salt, and no calcium or potassium chloride. Pour it around the edge of the pool, not into the skimmer, brush, and run the pump 24 hours before you trust a reading. The manual says to switch the cell off while adding any chemical, salt included.
Setting the output
The output is the share of the pump's run time that the cell makes chlorine, from 1 to 100 percent. Press LESS or MORE, and the number flashes. Each press moves it 1 percent, and holding moves it 5.
The manual's start-up:
- Shock the pool with chlorine from outside first. If new water has a high demand, the cell can't make enough to reach breakpoint.
- Wait until free chlorine is back to 2.0 to 4.0 ppm, then switch the cell on.
- Set the output to 60 percent.
- Test after 24 hours, and raise or lower it. Leave 24 hours between changes.
With a pump timer, Pentair suggests starting at 12 hours a day. At 8 percent or less, the cell runs only once an hour. Boost, both buttons together, runs it at 100 percent for the next 24 hours of pump time. Raise the output after heavy rain, in hot weather and with more swimmers.
Below 52°F, plus or minus 3, it stops. The CELL light goes red and the display reads COLD.
The cell reverses its polarity to shed scale every 3 hours. To set 4 or 5, hold LESS until "3 Hrs" shows, then use MORE or LESS.
The manual's water targets: free chlorine 2.0 to 4.0 ppm, pH 7.2 to 7.8, alkalinity 80 to 120, calcium 200 to 400, cyanuric acid 30 to 50, and none indoors. Nitrates should stay under 10 ppm, phosphates under 125 ppb, and metals at zero. It says not to use dry acid where heavy evaporation and little fresh water let its by-products build up.
Cleaning the cell
Self-cleaning slows scale but doesn't always stop it. The manual says to take the cell out and look through it every two months, more often in hard water. If it's clean after four months, at least twice a year.
Spray loose scale out with a garden hose first. If the blades are still crusted, acid-wash them. Power off and disconnect the cell. Mix 1 quart of muriatic acid into 1 gallon of water. Thread the acid cleaning kit's stand onto the cell, stand it in a bucket, and pour the acid in over the blades. Stop when the foaming stops, and never leave it more than 30 minutes. Rinse it inside and out.
If it needed acid, have the water tested for calcium and balance.
What the display and lights mean
- COLD, CELL light red: the water is below 52°F. No chlorine until it warms.
- CELL, CELL light flashing green: inspect the cell. It may be scaled, or the salt may be low in cold water. High nitrates, phosphates or metals can cause it too. Pentair says to add salt to 3,600 and warm the water above 60°F if possible.
- CELL light short red flashes: the temperature sensor has failed, and the salt reading may be wrong. EasyTouch shows salinity as 0000. Replace the flow switch, which carries the temperature sensor.
- FLOW light red: not enough flow. Check the pump's prime, the baskets, the valves, the filter and the cell, and then the flow switch.
- FLOW light flickering: it's talking to an IntelliFlo pump. Nothing's wrong.
- AC, nothing else lit: the cell is getting AC power. It has to be on a PC100 or an iChlor 15 power pack.
- CELL and FLO alternating, CELL light blinking red: low current, and it has locked itself. Turn the pump off with the iChlor powered: the FLOW light must go red. If it stays green, replace the switch before running it again. Then check the cell for scale, and cycle the power.
- FLO, SALT and CELL blinking red, FLOW blinking green: it has found a bad flow switch and locked. Test the switch the same way. To clear the lock, press LESS, MORE, MORE, LESS, LESS, LESS.
- LOSS, SALT and FLOW blinking red: it lost contact with an IntelliFlo or IntelliCenter. It resumes when contact comes back, or clear it with the same code.
- No power at all: the fuse in the power center, the power coming in when the timer is on, or the transformer leads against the decal inside the cover.
Salt cell not producing chlorine covers the checks that apply to every brand.
Winter
It makes no chlorine below 52°F, and freezing water can damage the cell badly. Either keep the pump running or winterize: drain the pump, filter and lines, then take the cell out, clean it and store it.
Where you buy it
Nothing new: all four iChlor numbers are discontinued. The power pack, 522741Z, and the flow switch kit, 523100, are still in Pentair's 2025-2026 catalog. A few Amazon listings still name the cells and the iChlor 15 bundle, though search showed them unavailable. For a new cell, the replacements on the Plus and LT page are the ones to buy.
None of the iChlor numbers is on Pentair's TradeGrade list. The warranty is two years for one made after October 1, 2023, and three before that.
Where Pentair's documents disagree
- Low salt. The manual's salt-light section says the cell keeps making chlorine, about 25 percent less, down to 2,000 ppm. Its start-up section says that below 2,600 the low salt light comes on and the CELL light goes blank, because there isn't enough salt to make chlorine.
- The self-cleaning cycle. The text says it's factory set to "two (3) hours". The steps and the display start at 3.
- The iChlor 15 power pack. The manual says it turns AC into the low-voltage DC the cell needs, but its specifications give the output as 24 VAC. A cell fed AC shows AC on its display as a fault.
- Total dissolved solids. The chemistry table gives 3,000 minimum to "5700 to 6000" maximum. The monthly service steps give 3,000 to 6,000.
- The iChlor 15's replacement. The catalog names the LT15 cell alone. Pentair's Plus and LT manual says an LT15 on an old iChlor power pack is ruined, so the cell with its own pack, 523744, is the safe one.
Which model do you have?
The model number is on the salt cell label. Everything else in the range is shared — these are the parts that change with it.
| Model | SKU | Pool size | Chlorine per 24 hr | Power |
|---|---|---|---|---|
| iChlor 30 with power center | 523081 | 30,000 gal | 1.0 lb | PC100 power center |
Note on iChlor 30 with power center: The cell with a PC100 power center, 520556. Rated for 30,000 gallons. Discontinued: Pentair's 2025-2026 catalog names 523733, the PLUS30 with a PC100, as its replacement. | ||||
| iChlor 30 cell only | 523009 | 30,000 gal | 1.0 lb | PC100 power center |
Note on iChlor 30 cell only: The cell alone, for an existing PC100. Discontinued; the catalog's replacement is 523730, the PLUS30 cell. | ||||
| iChlor 15 with power pack | 523080 | 15,000 gal | 0.6 lb | Own power pack |
Note on iChlor 15 with power pack: The cell with its own power pack, 522741Z, which plugs into a 110 V GFCI outlet. Rated for 15,000 gallons. Discontinued; the catalog's replacement is 523744, the LT15 with its own power pack. | ||||
| iChlor 15 cell only | 523010 | 15,000 gal | 0.6 lb | Own power pack |
Note on iChlor 15 cell only: The cell alone. Discontinued; the catalog names 523741, the LT15 cell, but an LT15 can't run on the iChlor 15's power pack. See Replacing a worn-out cell. | ||||
Pentair iChlor warranty
2 years if made after October 1, 2023; 3 years if made before
Pentair's warranty table gives an iChlor made after October 1, 2023 two years, whether it's a bundle with its power supply or a cell alone, and one made before that date three years, with or without a power center. An iChlor without a power center doesn't need professional installation; anything else that needs it and doesn't get it drops to one year, parts only. Bought on the internet, including from Pentair's authorized online resellers, it's one year, parts only, with no labor, and it can't count toward the three-year bundle warranty. None of the four iChlor numbers is on Pentair's TradeGrade list, revised October 23, 2026; the PC100 power center, 520556, is.
Manufacturer’s termsPentair iChlor parts, and what goes wrong
Read off the manufacturer’s parts list and checked before it ships. Open a row for what a bad one actually does — or start from the symptom and work down, which is the cheaper order.
What is it doing?
The cell alone, for an existing PC100. The manual expects about 10,000 hours, roughly five years of average use, and diagnostic mode shows the hours: hold MORE for 3 seconds. Pentair's catalog marks it discontinued and names the PLUS30 cell, 523730, as the replacement. The PLUS30 is the same length, plugs into the same PC100 and uses the same unions; the Plus and LT page covers it.
The cell alone, for the iChlor 15's own power pack. Discontinued. The catalog names the LT15 cell, 523741, as the replacement, but Pentair's Plus and LT manual says an LT15 connected to an older IntelliChlor or iChlor power pack is permanently damaged. Replace the pair: the LT15 with its own power pack is 523744.
Plugs into a 110 V GFCI outlet that's switched with the pump, and feeds the iChlor 15 over a 15-foot cord. It's only for the iChlor 15 cell: the manual warns that any other iChlor cell plugged into it causes severe damage. An old IntelliChlor IC15 power pack can't run an iChlor, and the cell shows AC if it's tried. Pentair's replacement steps: power off at the breaker, unplug the old pack and unfasten the cell cable, mount the new one on a vertical surface within 15 feet of the cell, connect the cell cable firmly, plug it in and restore power. The 2025-2026 catalog still lists it.
Turns AC into the low-voltage DC the cell needs. Mount it vertically within 15 feet of the cell. It must get power only when the pump runs, from the load side of a time clock, switch or relay. Inside is a 10 A replaceable fuse, with its details on the wiring label inside the cover. The manual's no-power checks are that fuse, the 110 or 220 V coming in when the timer is on, and the transformer leads against the decal. The IntelliChlor IC20 to IC60 use the same power center.
One switch reads both flow and water temperature. To test it, turn the pump off with the iChlor powered: the FLOW light must go red. If it stays green with no flow, replace the switch or take the iChlor out until you can, because the manual says not to run it with a faulty switch. Pentair's kit guide: power off, take off the switch cover and keep it, cut the old cable close to the switch, and unscrew it with a 1-3/16 inch wrench. Fit the new one hand tight plus one or two turns, with the arrows on its nut pointing with the flow. Join the red, white and black wires to their matches with the watertight connectors in the kit, and cap the cell's green wire in the fourth. Switches made before September 2018 don't fit cells made after it.
A stand and o-ring that thread onto the cell so diluted acid can be poured in over the blades. The manual's mix is 1 quart of muriatic acid to 1 gallon of water, acid into water, in a plastic bucket, with gloves and eye protection. Pour it in until the blades are covered, let it foam, and stop when the foaming stops, or at 30 minutes at most, since longer damages the blades. If it doesn't foam hard, the cell didn't need cleaning. Rinse inside and out and inspect.
Made by another company to fit 523103, not by the original maker.
The iChlor manual gives no number for the two unions and o-rings that come with the cell. Pentair says the thread size and unions are the same across the IntelliChlor, iChlor, Plus and LT, and the IntelliChlor's union kit is 520595. Check the o-rings are seated when the cell goes back in.
A blank that goes in place of the cell after new construction, for 30 days, to flush debris out of the pipes and give the plaster time to cure. Then it comes out and the cell goes in.
The lid over the display and buttons, one of the two replacement parts the manual lists.
Pentair iChlor manuals and documentation
Hosted by the manufacturer. These open on Pentair’s own servers, so they stay current.
- iChlor salt chlorine generator installation and user's guide (P/N 522709 Rev. G, 7/21/23)manual
- iChlor product page: 523009, 523010, 523080 and 523081, pointing to the IntelliChlor Plus and LT as the replacementspec
- Power pack replacement kit for iChlor 15 (P/N 523499 Rev. B, 3/28/25)manual
- IntelliChlor and iChlor flow-temperature switch replacement kit installation guide (P/N 520737 Rev. G, 10/18/19)manual
- iChlor test kit installation instructions (P/N 523450, 4/2019)manual
- Pentair Pool 2025-2026 product catalog, sanitizers: the legacy IntelliChlor and iChlor on page 248, each number discontinued with its replacementspec
- Pentair TradeGrade SKU list (revised October 23, 2026)spec
- Pentair pool and spa equipment warranty informationspec
Pentair iChlor complete parts list
Every part number the manufacturer lists for this equipment, from its own documents. Marked rows are the ones covered above with a symptom and a diagnosis.
| Part | Description | Note |
|---|---|---|
| 523081 | iChlor 30 with PC100 power center | Discontinued; replacement 523733 |
| 523009 | iChlor 30 cell only what goes wrong Amazon listing for 523009 | Discontinued; replacement 523730 |
| 523080 | iChlor 15 with power pack Amazon listing for 523080 | Discontinued; replacement 523744 |
| 523010 | iChlor 15 cell only what goes wrong | Discontinued; the catalog names 523741, which needs its own LT15 power pack |
| 522741Z | Power pack, iChlor 15 what goes wrong | Still in the 2025-2026 catalog |
| 520556 | PC100 power center, iChlor 30 what goes wrong Amazon listing for 520556 | Shared with the IntelliChlor IC20 to IC60 |
| 523100 | Flow-temperature switch kit, iChlor what goes wrong | Still in the 2025-2026 catalog |
| 523103 | Acid cleaning kit: stand and o-ring what goes wrong Aftermarket on Amazon listing for 523103 | |
| 520595 | Union kit, two what goes wrong Amazon listing for 520595 | The IntelliChlor's number; Pentair says the unions are the same |
| 522965 | Spacer cell what goes wrong | |
| 522680Z | Control panel lid what goes wrong | |
| 523449 | Test kit: stand, o-ring and flow switch activator, for testing a cell on the bench |