Pentair · ETi
Pentair ETi 250 High-Efficiency Heater
Pentair's compact 250,000 BTU condensing gas heater: the altitude limits on gas and propane, the neutralizer timer and bypass, and what its error codes mean.

The ETi 250 is Pentair's compact condensing gas heater: 250,000 BTU in, a titanium heat exchanger, and a two-line LCD control panel with a full menu. Pentair lists one version, 461112, factory set for natural gas. At 25 by 25 by 32 inches and 270 pounds, it's much smaller than the ETi 400, which is 30 by 34 by 42 inches and 379 pounds.
Pentair's catalog says its plumbing aligns exactly with the MasterTemp and Max-E-Therm, making it a drop-in replacement on tight equipment pads.
It's a professional install. Pentair's manual says a technician qualified in pool heater installation must install and service it, and that improper installation voids the warranty. What follows is what an owner should know.
Efficiency depends on the fuel
Pentair's headline is up to 96% thermal efficiency, and the footnote explains the "up to": the ETi 250 is 94% efficient on natural gas and 96% on propane with the conversion kit.
Altitude limits
The manual's first page sets hard limits, and says its 2,000 foot limit for propane, from the latest testing, supersedes anything in Pentair's other documents:
- Natural gas, up to 2,000 feet: as shipped.
- Natural gas, 2,000 to 10,000 feet: the high altitude conversion kit, 462057, must be installed. Pentair says gas flow has to be reduced at altitude for proper combustion and to avoid ignition problems.
- Propane: conversion kit 476370, and never above 2,000 feet.
- Above 10,000 feet: don't install it at all.
Pentair's warning is that getting this wrong can cause carbon monoxide poisoning or death.
What condensing means for an owner
The ETi 250 is a condensing appliance: its flue gases produce water while it runs.
- The water is acidic, pH 3.1 to 4.2. Pentair recommends its neutralizer kit, 476375, and says damage from untreated condensate isn't its responsibility.
- The drain needs a trap so flue gas can't escape through it. With no neutralizer fitted, Pentair says the condensate tubing must run through the heater's P-trap bracket.
- The heater has to sit level for that trap to work.
- Outdoors, it's for non-freezing weather. Pentair says not to operate it outdoors below 32°F, since the condensate line and trap can freeze and shut it down.
The flow window, and the automatic bypass
Pentair's manual rates the ETi 250 at 30 to 120 GPM, with a temperature rise across the heater of 25 to 35°F. For two or more heaters plumbed in parallel, it recommends 60 to 80 GPM each.
- Above 120 GPM, install a manual bypass valve before the heater, set it, then remove the handle or lock it.
- Paired with an IntelliFlo VSF pump, Pentair offers an automatic bypass using an IntelliValve actuator, kit 462048, which it says can add heater life and cut running costs. With BP-VALVE enabled in the menu, the valve takes 30 seconds to close on a call for heat, then after heating keeps water flowing through the exchanger for a one-minute cool-down before bypassing it again.
- A two-speed pump on low sometimes can't make enough pressure. Run it on high, and if that doesn't work, don't run the heater; correct the installation.
- Don't run it while an automatic cleaner runs. Pentair says a plugged suction line can starve the heater, and not to rely on the pressure switch to catch it.
- Water goes pump, filter, heater, pool. Plumbed backward, Pentair says, it cycles continuously.
After start-up, the outlet pipe should feel only slightly warmer than the inlet. If it's hot, or you hear boiling, flow is too low: check the filter, and if the temperature stays high, turn the heater off and call a technician. Pool heater not heating covers flow problems across makes.
The control panel and its menu
The display shows the water temperature on the first line and the setpoint on the second. POOL/SPA switches between the two, HEATER OFF turns the heater off, the arrows change the setpoint, and MENU/BACK and SELECT move through the menu. The HEATING light is solid while the burner fires and blinks during ignition.
The thermostat sets from 65°F to 104°F, and the setpoint has to be above the water temperature for the burner to fire. Pentair's factory settings are 70°F for pool and 95°F for spa.
The menu includes:
- POOL MAX and SPA MAX: the highest temperature each can be set to.
- HISTORY: the last five errors.
- CYCLES and RUNTIME: heater starts, and hours spent heating.
- RNC ALERT, RNC TIME and RNC RESET: the 1,000-hour neutralizer cartridge timer. Turn the alert off if you don't use a neutralizer.
- SFS TEMP: the current stack flue temperature.
- FLAME: the flame sensor's status, Normal or Low.
- HTR ADDR: the heater's address, 1 to 16, for automation.
- BP-VALVE: the automatic bypass, on or off.
Automation and timers
The ETi 250 connects to Pentair IntelliCenter over RS-485, up to 16 heaters, each with its own address set from the heater's menu. While IntelliCenter is in control, the heater's buttons are inactive, the display reads "RS485 Control", and alarms show on IntelliCenter's screens.
It can also be controlled through the fireman's switch terminals with a 2-wire control or a timer. Pentair says a pump timer should cut the call for heat 15 to 20 minutes before the pump shuts off, and that the connection must be a dry contact: powering it externally can damage the heater and isn't covered by the warranty.
What the error codes mean
- ERR PS: the water pressure switch is open, which means not enough flow.
- ERR AFS: the air flow switch, which checks the combustion blower.
- ERR HLS: the high limit switch opened, above 135°F at the exchanger outlet.
- ERR AGS: the automatic gas shut-off switch opened, above 150°F. Cycle the power to reset.
- ERR SFS: flue gas above 170°F. Cycle the power to reset.
- E06: a shorted stack flue sensor. E05: an open one.
- E01: an open water temperature sensor. 126: a shorted sensor, or water above 125°F.
- ERR CFS: the condensate float switch opened, usually a blocked drain or neutralizer.
- ERR IGN: the flame sensor. Cycle the power to reset.
- ERR FT: a thermal fuse opened.
- RNC flashing: the neutralizer timer has passed 1,000 hours of heating. Reset it from RNC RESET, or turn the heater off and hold HEATER OFF for 5 seconds.
Pentair's manual says only qualified technicians should troubleshoot the heater.
Where it can go
The placement rules match the ETi 400's:
- At least 5 feet from the inside of the pool or spa, unless a solid fence, wall or other permanent barrier separates them.
- Outdoors, in an open area on a level surface, away from debris, sprinklers, roof runoff and prevailing wind.
- Under an overhang, at least 3 feet between it and the top of the vent, open on three sides, and never under a deck.
- At least 36 inches from an air conditioner, heat pump or another gas heater, and 30 inches clear in front for service.
- In a garage or utility room, with its base at least 18 inches off the floor.
- A propane heater never in a pit or low spot where gas could collect.
Maintenance
Every six months, and at the start of each season: check the panels and vent for blockages, keep the area clear of anything combustible or corrosive, test the 50 psi relief valve by lifting its lever, and test the water pressure switch.
Every 12 months: Pentair says to have a qualified technician inspect and clean the heat exchanger, check its thermal insulation, and inspect the spark electrode and flame sensor. Pentair's cleaning kit, 461109, runs a water-fed brush through the exchanger on a cordless drill, with the burner removed and the exchanger left in place.
The neutralizer: check the pH at the cartridge outlet once a year, and replace the media when it falls below your local water authority's minimum.
Water chemistry, and the warranty
Pentair's manual lists these ranges for the heater:
- Free chlorine: 1 to 4 ppm, ideally 2 to 3
- pH: 7.2 to 7.8, ideally 7.4 to 7.6
- Total alkalinity: 60 to 180 ppm, ideally 80 to 100
- Calcium hardness: 150 ppm minimum, ideally 200 to 250
- Salt: 2,000 to 5,000 ppm, ideally 3,200
- Cyanuric acid: less than 30 ppm, following local codes
- Bromine: 2 to 10 ppm, ideally 4 to 6
The manual says failing to keep to these ranges can cause early heat exchanger failure and will void the warranty. It also says never put chlorine tablets in the skimmer, which floods the heater with concentrated chlorine when the pump stops, and to put any chlorinator downstream with a check valve, R172288, between it and the heater.
Winter
Where it freezes, Pentair's steps are:
- Turn off power to the heater and pump at the breakers.
- Close the gas valves, inside and outside the heater.
- Open the drain at the bottom of the manifold and drain the exchanger and internal plumbing.
- If the heater sits below the pool's water level, close the isolation valves.
- Remove the water pressure switch and plug its port.
- Drain the manifold through the outlet pipe.
- Blow out the remaining water with a low-pressure blower, below 5 psi. Never use compressed air.
- Cover the air inlet grate with a plastic bag.
Freeze damage isn't covered. In spring, don't turn the heater on until water is circulating. Closing a pool for winter covers the rest of the system.
Parts and prices
Pentair's 2025-2026 catalog lists the heat exchanger at $7,234.13, a little more than the ETi 400's. The gas valve is $709.22, the ignition control module $399.97, the control board $251.80, and the neutralizer kit $262.58. The high altitude and propane kits are $72.93 each.
Buying one
Pentair lists no online EC- version. When checked, the only Amazon listing that looked like it, titled "Pentair 250k BTU Pool Heater" at $7,999, gave no model number, so this page has no store link.
Where Pentair's documents disagree
- The gas valve setting. The manual's gas section gives the ETi 250's valve a manifold pressure of 1.4 inches of water column; its burner troubleshooting table says to verify –0.2 inches, the ETi 400's figure.
- The hold-down kit. The parts list gives 462055; the installation section says to buy 476004, the ETi 400's kit.
- Buttons that aren't there. The operating instructions say to press POOL ON or SPA ON and warn about a SERVICE HEATER light. The ETi 250 has a POOL/SPA toggle and shows errors on its LCD.
- The neutralizer reminder. One page says the display shows REPLACE after 1,000 hours; another says RNC flashes.
- The thermal fuse code. ERR FT in the fault table; ERR TF in the safety controls text.
- When a flow switch is needed. One page says more than 1 foot above or below the deck; another allows resetting the pressure switch up to 3 feet.
- The lowest thermostat setting. 65°F in the control section, 68°F in the winter section.
- Chlorine and alkalinity. The text gives chlorine floors of 0.6 and 1.4 ppm and alkalinity of 100 to 140 ppm; the table gives 1.0 ppm and 80 to 100 ppm ideal.
- Salt. The table lists it twice, once as 3,000 to 4,500 ppm with 3,250 ideal, and once as 2,000 to 5,000 with 3,200 ideal.
- The membrane pad. 476201 in the 2022 manual, 461106 in the 2025-2026 catalog.
Which model do you have?
The model number is on the heater label. Everything else in the range is shared — these are the parts that change with it.
| Model | SKU | Gas as shipped | Propane conversion kit | High altitude kit | Input | Thermal efficiency | Water flow | Dimensions | Weight | Note |
|---|---|---|---|---|---|---|---|---|---|---|
| ETi 250 | 461112 | Natural gas | 476370, up to 2,000 ft | 462057, natural gas from 2,000 to 10,000 ft | 250,000 BTU/hr | 94% on natural gas, 96% on propane | 30 to 120 GPM | 25 in. L x 25 in. W x 32 in. H | 270 lb | One version, factory set for natural gas. Pentair rates it 94% efficient on natural gas and 96% on propane with the conversion kit. |
Pentair ETi 250 High-Efficiency Heater parts, and what goes wrong
Read off the manufacturer’s parts list and checked before it ships. Open a row for what a bad one actually does — or start from the symptom and work down, which is the cheaper order.
What is it doing?
The menu's FLAME item shows the sensor's status as Normal or Low. Pentair's burner troubleshooting says a normal-looking flame that won't stay lit means flame current isn't being sensed: check for a wet or damaged igniter, a poorly grounded burner, or a failed ignition control module, 476385. The manual calls for an annual inspection of the flame sensor and spark electrode, 476081Z. $72.10 US list.
Live pricing arrives when the retailer programs are approved.
The ETi 250 has two thermal fuses wired in series: one for the heat exchanger coils and one for the flue gas leaving the exchanger. The stack flue sensor, 475601Z, shuts the heater down first if the flue gas passes 170°F. $114.59 US list.
Live pricing arrives when the retailer programs are approved.
The ETi 250 has one. It stops the burner firing when flow is restricted; Pentair says to check the filter first, and to call a technician if the message stays after that. It's factory set at 3 psi for a heater at pool level. A heater more than 1 ft above or below the water needs it reset by a technician, and beyond 3 ft a flow switch has to replace it. Never bypass it. $133.13 US list.
Live pricing arrives when the retailer programs are approved.
The condensate runs at pH 3.1 to 4.2, and Pentair recommends neutralizing it, warning that pH 5 or below can harm drains and pipes. The heater's menu has a 1,000-hour RNC timer; when it runs out, RNC flashes on the display. The kit's instructions say to check the pH at the cartridge outlet once a year with test strips or a meter, and replace the media when it falls below your local water authority's minimum. Indoors, mount it outside the heater, out of direct sunlight; outdoors, on the heater base. With no neutralizer, the condensate tubing must run through the P-trap bracket, so flue gas can't escape through it. $262.58 US list, as 476375Z in the catalog.
Live pricing arrives when the retailer programs are approved.
A reed float switch that shuts the heater down when condensate backs up in the exhaust, which Pentair's manual puts down to a blocked drain hose or neutralizer cartridge. The drain tubing has to slope continuously down, with no spirals, and the heater has to sit level for the P-trap to work. $367.84 US list.
Live pricing arrives when the retailer programs are approved.
Factory set at a manifold pressure of 1.4 inches of water column, which Pentair says differs from its other heaters. Replace it only with an identical valve with the same part number, and never adjust the regulator. Pentair warns never to fit the ETi 250's valve, identified by a yellow label and locking connectors, to any other Pentair heater, because of the risk of fire and carbon monoxide. $709.22 US list.
Live pricing arrives when the retailer programs are approved.
$7,234.13 US list in Pentair's 2025-2026 catalog, the most expensive part in the heater. Pentair's troubleshooting table blames boiling or bumping in the exchanger on low water flow, a plugged exchanger or a bypass valve stuck open. The manual says to have it inspected and cleaned every 12 months, and Pentair sells a cleaning kit for it, 461109: a brush turned by a cordless drill with water running through it, used with the burner removed but the exchanger left in place. Exchanger damage from water chemistry isn't covered by the warranty.
Live pricing arrives when the retailer programs are approved.
The main drain at the bottom of the manifold adapter. For winter, Pentair's steps open it to drain the exchanger, internal plumbing and manifold, then use a low-pressure blower to clear the rest. It goes back in before the heater returns to service.
Live pricing arrives when the retailer programs are approved.
Pentair ETi 250 High-Efficiency Heater manuals and documentation
Hosted by the manufacturer. These open on Pentair’s own servers, so they stay current.
- ETi 250 high efficiency pool heater installation and user's guide (P/N 476361 Rev. B, 2022)manual
- Pentair Pool 2025-2026 product catalog, ETi 250 ordering table on page 86, replacement parts and list prices on pages 372 to 377spec
- ETi 250 heat exchanger coil cleaning kit instructions (P/N 476453.A)guide
- ETi 250 condensate neutralizer kit instructions (P/N 476455.A)guide
- ETi 250 propane conversion kit instructionsguide
- ETi 400 and ETi 250 family brochure (P1-798)spec
- ETi 250 product page, with the item and accessory tablesspec
- Pentair pool product warranty informationguide
Pentair ETi 250 High-Efficiency Heater warranty
3 years parts, 3 years labor
Three years parts and labor, per Pentair's product page and catalog. Pentair's manual says the heater must be installed and serviced by a professional qualified in pool heater installation, and that improper installation or operation voids the warranty. The manual also excludes freeze damage and heat exchanger damage from water chemistry, says combustion air contaminated by chemical fumes voids the warranty, says a gas line union inside the cabinet voids it, and says an externally powered fireman's switch connection isn't covered. Pentair's warranty page gives products bought online one year, parts only; the ETi 250 has no online EC- item. O-rings and gaskets are consumables, with one year of parts and labor.
Manufacturer’s termsPentair ETi 250 High-Efficiency Heater complete parts list
Every part on the manufacturer’s exploded diagram, in their numbering. Marked rows are the ones covered above with a symptom and a diagnosis.
60 parts
| No. | Part | Description | Note |
|---|---|---|---|
| 1 | 476384 | Control board | |
| 2 | 461106 | Membrane pad | Listed as 476201 in the 2022 manual |
| 3 | 475985 | Automatic gas shut-off switch, 150°F | |
| 4 | 476365 | Air pressure switch | |
| 5 | 475601Z | Stack flue sensor | |
| 6 | 476364 | Wire harness | |
| 7 | 475998 | Thermal switch and fuse what goes wrong | |
| 8 | 476081Z | Spark electrode | |
| 9 | 475982 | Spark electrode cables | |
| 10 | 476366 | Float switch kit what goes wrong | |
| 11 | 476367 | Heat exchanger and chimney gaskets and insulation | |
| 12 | 476417 | Heat exchanger screw kit | |
| 13 | 475979 | Plug, 120/240 V | |
| 14 | 475603 | Water temperature and pressure gauge | |
| 15 | 476369 | Natural gas orifice kit | |
| 16 | 476419 | Heater gasket kit | |
| 17 | 476371 | Air intake kit | |
| 18 | 476372 | Louver door panel | |
| 19 | 476374 | Water manifold door panel | |
| 20 | 476373 | Control side door panel | |
| 21 | 475611 | Latch assembly | |
| 22 | 476375 | Condensate neutralizer cartridge kit what goes wrong | |
| 23 | 476376 | Inlet plumbing assembly kit | |
| 24 | 476377 | Outlet plumbing assembly kit | |
| 25 | 476378 | Exhaust assembly kit | |
| 26 | 42001-0056S | Terminal board | |
| 27 | 32850-0099 | Fireman's switch fuse, 1.25 amps | |
| 28 | 42001-0053S | Thermistor, water sensor | |
| 29 | 42001-0060S | Water pressure switch what goes wrong | |
| 30 | 42001-0107S | Dual voltage transformer | |
| 31 | 475618 | Pressure relief valve | |
| 32 | 475619 | Control cover | |
| 33 | 475620 | Vent cap, exhaust | |
| 34 | 476380 | Water bypass assembly kit | |
| 35 | 475622 | Vent socket | |
| 36 | 476382 | TitanTough heat exchanger what goes wrong | |
| 37 | 476383 | Burner kit | |
| 38 | 476000 | Blower | |
| 39 | 476409 | Gas valve what goes wrong | |
| 40 | 38404-4097S | Union, 3/4 in. | |
| 41 | 42001-0063S | High limit switch | |
| 42 | U178-920P | Drain plug what goes wrong | |
| 43 | 476381 | Water manifold assembly kit | |
| 44 | 476420 | Manifold enclosure fasteners | |
| 45 | 462055 | Hold-down bracket kit | |
| 46 | 476370 | Propane conversion orifice kit | Up to 2,000 ft only |
| 47 | 476421 | Blower gasket | |
| 48 | 476385 | Ignition control module | |
| 49 | 462023Z | Flame sensor what goes wrong | |
| 50 | 476386 | Burner assembly kit | |
| 51 | 476389 | Control housing | |
| 52 | 461103 | Inlet brass fitting | |
| 53 | 461104 | Outlet brass fitting | |
| 54 | 476106 | Heat exchanger union adapter kit | |
| 55 | 476400 | Air manifold bracket | |
| 56 | 476401 | Air manifold | |
| 57 | 462057 | High altitude conversion kit | Natural gas, 2,000 to 10,000 ft |
| 58 | 461109 | Heat exchanger cleaning kit | In the manual's list, not the catalog's |
| - | 462048 | Smart heater bypass kit | Accessory, for the automatic bypass |
| - | 462065 | Accessories and documents bundle |