Pentair · MasterTemp
Pentair MasterTemp
Pentair's gas heater — the two-year term, the clearances, and why the EC- item number costs you the labor on any claim.

MasterTemp is Pentair's atmospheric gas heater, and it comes in five sizes: 175, 200, 250, 300 and 400. The number is not marketing. It is the input rating in thousands of BTU per hour, straight off Pentair's own model table. Pentair's other gas heater, the Sta-Rite Max-E-Therm, is built from most of the same parts in a different cabinet.
That matters because gas heaters are rated by what they burn, not by what they deliver. A MasterTemp 400 burns 400,000 BTU an hour and puts about 336,000 into the water, because the standard copper exchanger is 84% efficient. A heat pump's nameplate is already the delivered figure. Comparing the two numbers side by side makes a heat pump look half the machine it is, and the heater calculator does that conversion for you.
The minimum flow is the spec that catches people
Every model has a floor, and it is not the same floor:
- 175 — 20 GPM minimum
- 200 — 20 GPM minimum
- 250 — 25 GPM minimum
- 300 — 30 GPM minimum
- 400 — 40 GPM minimum
The ceiling is 120 GPM on every one of them.
A MasterTemp 400 needs 40 gallons a minute before it will run. That is the number nobody mentions when they tell you to run a variable-speed pump slowly to save money, and the two pieces of advice collide directly: the speed that makes the pump cheap to run may be below the speed the heater needs to fire at all.
The usual symptom is a heater that will not light, or lights and drops out, on a schedule that worked last season. That is the water pressure switch doing its job rather than failing. Before replacing anything, raise the pump speed and see if it fires. If it does, the fix is a heating speed on the pump schedule, not a part.
Pentair asks for a manual bypass valve above that 120 GPM ceiling, and notes that pumps of 2 HP and larger can push past it.
The heavy-duty version is less efficient, on purpose
This is the counterintuitive one, and it is worth understanding before paying more.
Pentair rates the standard copper heat exchanger at 84% and the heavy-duty cupro-nickel at 82%. The HD model is not a better heater. It is a more corrosion-tolerant one, and you give up two points of efficiency for that tolerance.
So the choice is not "premium or basic". It is about water. Cupro-nickel earns its keep on salt pools, on water that runs aggressive, and anywhere the first exchanger already failed from chemistry rather than age. On balanced water in a chlorine pool, the standard copper exchanger is both cheaper and slightly more efficient, and paying for HD buys you nothing you will notice.
If you do not know whether your water is the problem, the LSI calculator will tell you whether it is aggressive before you spend the money.
Protect the exchanger, because it is most of the heater
The heat exchanger is the expensive part, and it has two common ways of dying early. Both are preventable and neither is age.
Chemicals back-siphoning into it. Pentair requires the chemical feeder to be plumbed downstream of the heater, with a check valve — R172288 — between the two. Without it, concentrated chlorine sits against copper whenever the pump stops. An exchanger that failed in three years usually failed this way, and the check valve costs a rounding error against the coil.
Condensate corroding it from the outside. The thermal regulator bypasses cold water around the exchanger until it is warm enough not to sweat. When it sticks, the heater condenses internally and the water rots the metal from the flue side. Pentair's troubleshooting names a failed thermal governor directly as the cause of sweating, so a heater that drips inside is telling you about a cheap part before it costs you an expensive one.
One more, from the operating instructions: run the filter pump continuously while the heater is on, and for at least five minutes after it shuts off. That post-run is what carries residual heat out of the exchanger instead of leaving it to soak.
Find the manufacture date before ordering anything
The tub was redesigned, and the parts split at the date rather than the model.
Heaters built after 1/12/09 take different numbers from those built before — the heat exchanger most visibly. A 400 built after that date takes 474061; before it, 77707-0234. The 250 takes 474059 or 460747 on the same split. There are two further splits on the ASME versions, at 10/2012 and 11/16/13, and the combustion chamber parts split again between the clamp-lid tub and the nine-bolt lid.
The rating plate has the date. Read it before you order, because the exchanger is the most expensive part on the machine and the one most often ordered twice.
The controls split too, in May 2021. Pentair's 2025-2026 catalog gives heaters made before 5/5/2021 the five-button keypad, 472610Z, and heaters made after 5/6/2021 the six-button RS-485 keypad, 461106. The current manual lists the ignition control module as 476223, the RS-485 control board kit as 461105 and the harness as 461107. The older numbers from Pentair's 2016 parts sheets are still in the list below for older heaters.
One gap worth knowing about: the parts tables inside the owner's manual cover 175/200, 300 and 400 — the 250 is not in them at all. Its numbers are on Pentair's separate parts sheets, which are linked above and which do list it. If you own a 250 and the manual seems to have forgotten your heater, that is why.
Installation is not a DIY job, and the warranty says so
Worth being blunt, because most things on this site are jobs you can do yourself and this one is not.
This is a gas appliance that produces carbon monoxide and flue gases. Pentair's manual opens by saying improper installation or operation can cause serious injury or death, requires installation by qualified personnel, and states that improper installation voids the warranty. For indoor installations it strongly recommends carbon monoxide detectors nearby.
The specifics it sets, if only so you can check what was done: the heater needs a gas supply between 4 and 14 inches of water column, with at least 4 inches while running and no more than a 2-inch drop between static and running. Clearance from combustible surfaces is 6 inches at the top, the exhaust side, the header side and the door panels. Water connects directly to schedule 40 PVC, and the outlet plumbing must contain no shut-off valves or other restrictions.
Diagnosing it, cleaning the filter, checking flow and reading the rating plate are all yours. Gas fitting and venting are not.
Which model do you have?
The model number is on the heater label. Everything else in the range is shared — these are the parts that change with it.
| Model | SKU | Minimum flow | Tube sheet coil, after 1/12/09 | Manifold kit | Air blower, natural gas | Flameholder kit | Note |
|---|---|---|---|---|---|---|---|
| MasterTemp 175 | 460792 | 20 GPM | 474058 | 77707-0014 | 77707-0250 | 77707-0202 | 175,000 BTU/hr input. Propane is 460793. The smallest of the line and the only one with its own air blower and orifice numbers throughout. |
| MasterTemp 200 | 460730 | 20 GPM | 474058 | 77707-0014 | 77707-0251 | 77707-0202 | 200,000 BTU/hr input. Propane is 460731, and the ASME versions are 461000 and 461001. Shares its water system with the 175 but takes its own blower and orifice. |
| MasterTemp 250 | 460732 | 25 GPM | 474059 | 460748 | 460743 | 460746 | 250,000 BTU/hr input. Propane is 460733. Heavy-duty cupro-nickel is 460806, and the ASME versions are 460771 and 460772. Every one of its parts is its own number, and the manual's parts tables leave it out entirely — use the parts sheets linked below instead. |
| MasterTemp 300 | 460734 | 30 GPM | 474060 | 77707-0015 | 460757 | 77707-0203 | 300,000 BTU/hr input. Propane is 460735. |
| MasterTemp 400 | 460736 | 40 GPM | 474061 | 77707-0016 | 77707-0253 | 77707-0204 | 400,000 BTU/hr input, and the size most often sold residentially. Propane is 460737. Heavy-duty cupro-nickel is 460805, and the ASME versions are 460775 and 460776 in natural gas and propane, with 461021 as the ASME heavy-duty. The 400 is one of two sizes with a heavy-duty version — the 250 is the other. |
Pentair MasterTemp parts, and what goes wrong
Read off the manufacturer’s parts list and checked before it ships. Open a row for what a bad one actually does — or start from the symptom and work down, which is the cheaper order.
What is it doing?
The heat exchanger, and the single most expensive part of the heater. This is the number for a 250 built after 1/12/09; before that date the same job takes 460747, because the tub was redesigned. Get the manufacture date off the rating plate before ordering — this is the part people order twice.
Live pricing arrives when the retailer programs are approved.
Same part for the 400, again for heaters built after 1/12/09. The pre-2009 number is 77707-0234. The heavy-duty cupro-nickel version is 474065, which is the one to fit if the first exchanger died of water chemistry rather than age.
Live pricing arrives when the retailer programs are approved.
One number across every model and both fuels, which makes it one of the easier parts to get right. It is also a gas component on a gas appliance — replacing it is a job for someone qualified, and Pentair is explicit that improper service voids the warranty.
Live pricing arrives when the retailer programs are approved.
Hot-surface ignition, so there is no pilot to relight — when a MasterTemp stops lighting, the igniter is the first consumable to suspect. The kit includes the gasket, which is the part people leave out and then chase an air leak.
Live pricing arrives when the retailer programs are approved.
The switch that proves there is flow before the burner lights. A heater that will not fire on a variable-speed pump running slow is usually this switch doing its job rather than failing — check the flow against the minimum for your model before replacing it.
Live pricing arrives when the retailer programs are approved.
Trips on overheat, and overheat on this appliance nearly always means not enough water through it. Treat a tripping high limit as a flow problem first and an electrical one second.
Live pricing arrives when the retailer programs are approved.
The temperature sensor the control board reads. A drifting one gives you water that is not the temperature the panel claims — and Pentair notes separately that thermostats can be out by 4°F even when everything is healthy.
Live pricing arrives when the retailer programs are approved.
Holds the water in the exchanger above the dew point by bypassing cold water around it. When it sticks, the heater sweats internally and that condensate is what rots a heat exchanger from the outside. Pentair's own troubleshooting names a failed thermal governor as the cause of sweating.
Live pricing arrives when the retailer programs are approved.
Not part of the heater, and arguably the most important thing on this page. Pentair requires the chemical feeder downstream of the heater with this check valve between the two, because concentrated chlorine back-siphoning into a copper exchanger destroys it. An exchanger that failed in three years usually failed here.
Live pricing arrives when the retailer programs are approved.
If you are doing the job anyway
These get replaced together. Doing them in one pass costs a few dollars more and saves taking the same thing apart twice.
It will not light
The ignition path in the order Pentair's troubleshooting walks it: the igniter first because it is the consumable, then the switches that have to prove flow and temperature before the gas valve is allowed to open. Cheap parts, and between them they cover most no-fire calls.
- Igniter and gasket kit77707-0054
- Water pressure switch42001-0060S
- High limit switch42001-0063S
Heat exchanger replacement, 400
The exchanger does not go back in without new seals, and the o-ring kit costs a fraction of doing the job twice. Check the manufacture date first — this is the post-2009 number.
- Tube sheet coil assembly, 400474061
- 77707-011977707-0119
- 77707-012077707-0120
Protect the exchanger
Both of these exist to stop the expensive part dying early. The check valve keeps concentrated chemicals out of the copper, and the thermal regulator keeps the exchanger above the dew point so it does not corrode from condensate on the outside.
- Check valve, chlorinatorR172288
- Thermal regulator38000-0007S
Pentair MasterTemp manuals and documentation
Hosted by the manufacturer. These open on Pentair’s own servers, so they stay current.
- Installation and user's guide, MasterTemp 175 to 400manual
- MasterTemp product page — current order numbers, weights, and the copper and cupro-nickel efficiency figuresspec
- Replacement parts — water systemdiagram
- Replacement parts — burner systemdiagram
- Replacement parts — electrical system (2016, before RS-485)diagram
- Pentair Pool 2025-2026 product catalog: MasterTemp electrical parts and US list prices on page 384spec
Pentair MasterTemp warranty
2 years parts
Two years for the MasterTemp and Max-E-Therm, and one year in a commercial application — Pentair's warranty page halves it. MasterTemp is a Pentair TradeGrade product, so the coverage depends on where it was bought. Through a dealer it carries the full product warranty; the EC-prefixed item numbers are the versions approved for online sale, and Pentair's warranty page puts e-commerce products on one year, parts only, with labor not covered on internet purchases. On a heater, labor is most of the cost of any warranty repair, so that gap is worth more than the price difference. Pentair also states plainly that improper installation or operation voids the warranty — and this is an appliance that must be installed by qualified personnel, not a filter you can swap yourself.
Manufacturer’s termsPentair MasterTemp complete parts list
Every part on the manufacturer’s exploded diagram, in their numbering. Marked rows are the ones covered above with a symptom and a diagnosis.
137 parts
| No. | Part | Description | Note |
|---|---|---|---|
| 1 | 77707-0232 | Tube sheet coil assembly kit, 175 and 200 — before 1/12/09 | |
| 1 | 474058 | Tube sheet coil assembly kit, 175 and 200 — after 1/12/09 | |
| 1 | 460747 | Tube sheet coil assembly kit, 250 — before 1/12/09 | |
| 1 | 474059 | Tube sheet coil assembly kit, 250 — after 1/12/09 what goes wrong | |
| 1 | 77707-0233 | Tube sheet coil assembly kit, 300 — before 1/12/09 | |
| 1 | 474060 | Tube sheet coil assembly kit, 300 — after 1/12/09 | |
| 1 | 77707-0234 | Tube sheet coil assembly kit, 400 — before 1/12/09 | |
| 1 | 474061 | Tube sheet coil assembly kit, 400 — after 1/12/09 what goes wrong | |
| 1 | 77707-0244 | Tube sheet coil assembly kit, 400 HD — before 1/12/09 | |
| 1 | 474065 | Tube sheet coil assembly kit, 400 HD — after 1/12/09 | |
| 1 | 473710 | Tube sheet coil assembly kit, 250 HD — before 1/12/09 | |
| 1 | 474063 | Tube sheet coil assembly kit, 250 HD — after 1/12/09 | |
| 2 | 77707-0014 | Manifold kit, 175 and 200 | |
| 2 | 460748 | Manifold kit, 250 | |
| 2 | 77707-0015 | Manifold kit, 300 | |
| 2 | 77707-0016 | Manifold kit, 400 | |
| 2 | 474200 | Basic manifold kit | |
| 3 | 77707-0117 | Coil and tubesheet sealing o-ring kit, 175 and 200 — 6 off | |
| 3 | 460749 | Coil and tubesheet sealing o-ring kit, 250 — 8 off | |
| 3 | 77707-0118 | Coil and tubesheet sealing o-ring kit, 300 — 10 off | |
| 3 | 77707-0119 | Coil and tubesheet sealing o-ring kit, 400 — 12 off | |
| 8 | 77707-0001 | Manifold bypass valve kit | |
| 9 | 42001-0060S | Water pressure switch what goes wrong | |
| 9 | 473716Z | Water pressure switch, old header design ASME | |
| 13 | U9-226 | Connector tube o-ring | |
| 14 | 77707-0017 | Connector tube kit, with o-ring | |
| 15 | 77707-0010 | Thermal regulator kit | |
| 16 | 38000-0007S | Thermal regulator, with spring clip what goes wrong | |
| 18 | 35505-1313 | Thermal regulator cap o-ring | |
| 20 | U178-920P | Drain plug | |
| 21 | U78-60ZPS | Zinc plug | |
| 22 | 473715Z | Pressure relief valve | |
| 23 | PKG 188 | 2 in. union adapter package, 2 off | |
| — | 77707-0120 | O-ring kit | |
| 1 | 42001-0051S | Combination gas control valve kit what goes wrong | |
| 2 | 38404-4097S | ¾ in. union — 2 off | |
| 5 | 77707-0250 | Air blower kit, natural gas, 175 | |
| 5 | 77707-0251 | Air blower kit, natural gas, 200 | |
| 5 | 460743 | Air blower kit, natural gas, 250 | |
| 5 | 460757 | Air blower kit, natural gas, 300 | |
| 5 | 77707-0253 | Air blower kit, natural gas, 400 | |
| 5 | 77707-0254 | Air blower kit, propane, 175 and 200 | |
| 5 | 460744 | Air blower kit, propane, 250 | |
| 5 | 460758 | Air blower kit, propane, 300 | |
| 5 | 77707-0256 | Air blower kit, propane, 400 | |
| 7 | 460798 | Air orifice kit, 175 | |
| 7 | 77707-0111 | Air orifice kit, 200 | |
| 7 | 460745 | Air orifice kit, 250 | |
| 7 | 460759 | Air orifice kit, 300 | |
| 7 | 77707-0113 | Air orifice kit, 400 | |
| 15 | 474095 | One-piece metal chamber and combustion chamber assembly — clamp lid tub | |
| 15 | 474957 | One-piece metal chamber and combustion chamber assembly — 9-bolt lid tub | |
| 20 | 474094 | One-piece metal elbow and combustion chamber cover — clamp lid tub | |
| 20 | 474958 | One-piece metal elbow and combustion chamber cover — 9-bolt lid tub | |
| 20a | 474201 | Tub o-ring kit, clamp lid tub | |
| 20b | 474952 | Tub o-ring kit, 9-bolt lid tub | |
| 21 | 42002-0005S | Metal vent cover | |
| 22 | 42002-0034Z | Heater top | |
| 23 | 42002-0039Z | Side panel, service, with clips and screws | |
| 24 | 42002-0033Z | Side panel, manifold | |
| 25 | 42002-0031Z | Heater bottom | |
| 26 | 42002-0032Z | Side panel, flue stack | |
| 27 | 42002-0041Z | Junction box cover | |
| 28 | 474292 | Clips and screws set | |
| — | 77707-0011 | Blower and adapter plate gasket kit | |
| — | 77707-0202 | Flameholder kit, 175 and 200 | |
| — | 460746 | Flameholder kit, 250, with insert | |
| — | 77707-0203 | Flameholder kit, 300, with insert | |
| — | 77707-0204 | Flameholder kit, 400, with insert | |
| — | 77707-0008 | Insulation kit | |
| — | 42001-0074S | Lower enclosure insulation | |
| — | 461002 | Gas orifice kit, natural gas, 175 | |
| — | 77707-0431 | Gas orifice kit, natural gas, 200 | |
| — | 460739 | Gas orifice kit, natural gas, 250 | |
| — | 460753 | Gas orifice kit, natural gas, 300 | |
| — | 77707-0411 | Gas orifice kit, natural gas, 400 | |
| — | 460797 | Gas orifice kit, propane, 175 | |
| — | 77707-0461 | Gas orifice kit, propane, 200 | |
| — | 460740 | Gas orifice kit, propane, 250 | |
| — | 460754 | Gas orifice kit, propane, 300 | |
| — | 77707-0441 | Gas orifice kit, propane, 400 | |
| — | 460794 | Natural gas to propane conversion kit, 175 | |
| — | 77707-1461 | Natural gas to propane conversion kit, 200 | |
| — | 460741 | Natural gas to propane conversion kit, 250 | |
| — | 460755 | Natural gas to propane conversion kit, 300 | |
| — | 77707-1441 | Natural gas to propane conversion kit, 400 | |
| — | 460795 | Propane to natural gas conversion kit, 175 | |
| — | 77707-1431 | Propane to natural gas conversion kit, 200 | |
| — | 460742 | Propane to natural gas conversion kit, 250 | |
| — | 460756 | Propane to natural gas conversion kit, 300 | |
| — | 77707-1411 | Propane to natural gas conversion kit, 400 | |
| 1 | 42002-0035Z | Heater display cover | |
| 2 | 42001-0030S | Igniter bracket | |
| 3 | 77707-0054 | Igniter and igniter gasket kit what goes wrong | |
| 4 | 42001-0066S | Igniter gasket | |
| 5 | 42002-0025S | Automatic gas shutoff switch | |
| 6 | 42001-0063S | High limit switch what goes wrong | |
| 7 | 42001-0053S | Thermistor what goes wrong | |
| 8 | 42001-0056S | Terminal board | |
| 9 | 32850-0099 | Fireman's switch fuse, 1.25 A | |
| 10 | 476223 | Ignition control module kit | In the current manual and the 2025-2026 catalog, $561.27 US list. The kit's adapters fit it to older heaters |
| 10 | 42001-0052S | Ignition control module, older heaters | On Pentair's 2016 parts sheet |
| 11 | 42001-0107S | Transformer, 115/230 V | |
| 12 | 42001-0061S | Air flow switch | |
| 13 | 461105 | RS-485 control board and membrane pad kit | In the current manual and catalog, $1,024.08 US list |
| 13 | 42002-0007S | Control board kit, before RS-485 | On Pentair's 2016 parts sheet |
| 15 | 461106 | Six-button membrane keypad, RS-485 | Heaters made after 5/6/2021, per the 2025-2026 catalog |
| 15 | 472610Z | Five-button membrane keypad | Heaters made before 5/5/2021, per the 2025-2026 catalog |
| — | 476211 | RS-485 combo conversion kit, for heaters without RS-485 | |
| 16 | 42002-0024S | Stack flue sensor | |
| — | 461107 | Heater wiring harness, 115/230 V | In the current manual and catalog |
| — | 42001-0104S | Heater wiring harness, 115/230 V, before RS-485 | On Pentair's 2016 parts sheet |
| — | 42001-0105S | 120/240 volt plug kit | |
| — | R172288 | Check valve, between heater and chlorinator what goes wrong | |
| — | 472648Z | Bypass access plug | ASME |
| — | 474096 | Heat exchanger kit, 400 | ASME, built after 3/24/09 — tub design with clamp ring |
| — | 474956 | Heat exchanger kit, 400 | ASME, built after 11/16/13 — nine-bolt tub design |
| — | 474350 | Heat exchanger kit, 400 HD | ASME, built after 3/24/09 — tub design with clamp ring |
| — | 474953 | Heat exchanger kit, 400 HD | ASME, built after 11/16/13 — nine-bolt tub design |
| — | 474097 | Heat exchanger kit, 250 | ASME, built after 3/24/09 — tub design with clamp ring |
| — | 474955 | Heat exchanger kit, 250 | ASME, built after 11/16/13 — nine-bolt tub design |
| — | 474349 | Heat exchanger kit, 250 HD | ASME, built after 3/24/09 — tub design with clamp ring |
| — | 474954 | Heat exchanger kit, 250 HD | ASME, built after 11/16/13 — nine-bolt tub design |
| — | 460923 | Bypass valve kit | ASME, built before 10/2012 — old header design |
| — | 461007 | Bypass valve tool kit | ASME, built before 10/2012 — old header design |
| — | 460924 | Thermal regulator kit, with spring clip | ASME, built before 10/2012 — old header design |
| — | 462048 | Automatic bypass valve kit | |
| — | 460925 | Pressure relief valve, ¾ in. | |
| — | 460738 | Bolt-down bracket kit | For areas subject to hurricanes or very high winds |
| — | 461031 | Combustion air intake duct connection kit | All models |
| — | 467107Z | Gas pipe escutcheon, PVC | Required on installation |
| — | 270114Z | Phillips retention screw, #8, for the escutcheon | Required on installation |
| — | 476150Z | Rodent-resistant parts list, item 30 | Heaters built 1/12/2009 to 10/31/2013, clamp lid tub design |
| — | 476155Z | Escutcheon, rodent-resistant parts list | Heaters built 1/12/2009 to 10/31/2013, clamp lid tub design |
| — | 462037Z | Rodent-resistant parts list, item 31 | Standard heater. ASME heaters take 462038Z instead |
| — | 462038Z | Rodent-resistant parts list, item 32 | ASME heater only |
| — | 520818 | COM port expansion module | Adds three ports |
Buy the heater
One retailer for now. More get added here as their programs are approved, and this becomes a comparison rather than a link.